HjemGraphtecGraphtec GS-TH Temperature & Humidity Sensor for GL100 logger -20ºC to 85ºC, 0.0 - 100.0% RH

Graphtec GS-TH Temperature & Humidity Sensor for GL100 logger -20ºC to 85ºC, 0.0 - 100.0% RH

Graphtec GS-TH Temperature & Humidity Sensor for GL100 logger -20ºC to 85ºC, 0.0 - 100.0% RH
 
Klik på billedet for at forstørre
 
Graphtec GS-TH Temperature & Humidity Sensor for GL100 logger -20ºC to 85ºC, 0.0 - 100.0% RH
 
 
 
 
 
 
 
 

 

 

 

842 DKK

 
 

 

Item

Description

 

GS-TH

Relative Temperature and Humidity Sensor

 

Measurement Data

Temperature, Humidity, Dew Point Temperature (calculated value)
Accumulated Temperature ºCh
Accumulated Temperature only recorded

Measurement Range

±2G (20m/s2, ±5 (50m/s2, ±10 (100m/s2
(Gravitational Acceleration 1G=approx. 9.807m/s

 

Measuring Method

C-MOS sensor

Range of Temperature Measurement

-20ºC to 85ºC

Temperature Measurement Degree of Accuracy

-20 ≤TS < 0 ±0.8(ºC)
0 ≤TS < 60 ±0.5(ºC)
60 < TS ≤85 ±0.8ºC

Range of Humidity Measurement

0.0 - 100.0% RH

Humidity Measurement Accuracy

At 25ºC
±1.0% RH (0-10% RH)
±8% RH (10-20% RH)
±5% RH (20-80% RH)
±8% RH (80-90% RH)
±10% RH (90-100% RH)

Response Time (Temperature)

Temperature, Humidity: approx. 100 seconds to reach 63% at 25ºC with airflow speed of 1m/s(1)

Processor Functionality

Accumulated Temperature: 0 to 999,999kº ch(2)

Memory Capacity (Memory Mode)

16 | 32 | 64 | 128k sample

Pre-trigger
(Memory Mode)

OFF/10 | 25 | 50 | 100 % of selected memory

Sampling Interval

0.5 | 1 | 2 | 5 | 10 | 20 | 30 sec
1 | 2 | 5 | 10 | 20 | 30 | 60 min

Alarm

OFF/level

Temperature Unit of Denomination

ºC/ºF (selectable)

Waterproofing

Waterproof protection filter at the connection point.

 

Operating Environment

Within range of Temp/Humidity measurement.

External Dimensions

15mm x 45mm x 10.2mm (excludes protrusion)

Weight

Approx. 14g.

 


 
 
 
 
 